Working on a OBI Apps project, I was getting the DAC configurations ready and bumped into the following error message, stating “Error whle calculating build information!”.  The message stated “MESSAGE:::No physical folder information found for PLP”.   This occured when I was trying to build my newly created execution plan.

[simage=103,576,y,center]

Solution

I had created a new execution plan and added my subject area(s) but forgot to click the “Generate” button on the Parameters sub-tab after I had selected the subject areas that I wanted built for that particular execution plan.  To fix the error, I just highlighted the newly created execution plan, clicked the Parameters sub-tab and clicked “Generate “

This is a very low level issue for the DAC but the issue and solution were worth mentioning.  This occured on the DAC Windows client version 10.1.3.4.1.

Contact Us
Christian Screen
Christian is an innovator in analytics and data warehousing design, best practices, and delivery. With more than fifteenyears of decision support and data warehousing with key experiences at Office Depot HQ, Sierra-Cedar, and Capgemini, he oversees the Oracle Analytics Practice which includes the technical development and delivery of Oracle BI collaboration software, data warehouse solutions, Oracle BI/EPM projects, and packaged analytics solutions at Datavail.

Leave a Reply

Your email address will not be published.
Required fields are marked (*).

3 thoughts on “Art of BI: DAC Error Message – No Physical folder information found for PLP”
  1. It is an old post, but it saved me a lot of time because i could not figure what the problem was. Thank you for sharing this !